Emergency Planning at Seabrook Nuclear Powerplant: Hearing Before the Subcommittee on Energy Conservation and Power of the Committee on Energy and Commerce, House of Representatives, Ninety-ninth Congress, Second Session November 18, 1986U.S. Government Printing Office, 1987 - 707 pages |
À l'intérieur du livre
Résultats 1-5 sur 97
Page 3
... staff admonished the utility that it was going down the wrong path when it attempted to justify its scheme on the basis of recent general source term research . Stress the uniqueness of Seabrook's containment , the NRC staff 3.
... staff admonished the utility that it was going down the wrong path when it attempted to justify its scheme on the basis of recent general source term research . Stress the uniqueness of Seabrook's containment , the NRC staff 3.
Page 4
... containment , the NRC staff coached the utility . Lo and behold , the utility presents the NRC staff with an expert study proposing to demonstrate that Sea- brook's containment is so safe that an accident with off - site conse- quences ...
... containment , the NRC staff coached the utility . Lo and behold , the utility presents the NRC staff with an expert study proposing to demonstrate that Sea- brook's containment is so safe that an accident with off - site conse- quences ...
Page 5
... containment is so unusually strong that a reduction in the size of the " emergency planning zone " ( EPZ ) around the plant is warranted . It has become apparent from public and internal agency documents as well as from comments offered ...
... containment is so unusually strong that a reduction in the size of the " emergency planning zone " ( EPZ ) around the plant is warranted . It has become apparent from public and internal agency documents as well as from comments offered ...
Page 6
... containment analysis techniques , some in response to inquiries by this Subcommittee , contradict the utility's claims that the Seabrook containment is so strong that it is virtually impossible that a severe accident with significant ...
... containment analysis techniques , some in response to inquiries by this Subcommittee , contradict the utility's claims that the Seabrook containment is so strong that it is virtually impossible that a severe accident with significant ...
Page 7
... containment performance , and related matters , and several illustrative comments regarding the need to plan for severe accidents ; and o a summary of technical issues that PSNH and the NRC staff may have ignored in their analysis of ...
... containment performance , and related matters , and several illustrative comments regarding the need to plan for severe accidents ; and o a summary of technical issues that PSNH and the NRC staff may have ignored in their analysis of ...
Autres éditions - Tout afficher
Expressions et termes fréquents
adequate Amesbury applicant assessment ATKINS beach Board of Selectmen Chairman Chernobyl Chernobyl accident Civil Defense communities concerning Conservation and Power containment decision Derrickson Dignan Director discuss documents emergency evacuation Emergency Planning Sensitivity emergency planning zone emergency preparedness emergency response plans Energy Conservation evacuation plan event exercise failure FEMA Governor Dukakis Hampshire Yankee health and safety hearing letter Licensing Board low-power testing MARKEY Massachusetts meeting Memo memorandum November 18 NRC staff NRC's nuclear plant nuclear power plant Nuclear Regulatory Commission Office offsite emergency operating participation planning and preparedness probabilistic risk assessment procedures protective action PSNH public health Public Service questions radiation radioactive Radiological Emergency Response reactor regarding regulations release Representative request RERP risk Seabrook nuclear power Seabrook plant Seabrook Station severe accident Shoreham source term SSPSA Update Stratham Subcommittee on Energy submitted Sununu technical Three Mile Island town utility VOLLMER WINGO